Special features
- Master-slave operation
- Parallel operation (0-4A)
- Serial operation (0-60V)
- Tracking operation (±30V)
- Pre-defined curve progressions for sinus, square, triangle, sawtooth, PWM
- Arbitrary function for free programming of voltage and current progressions
- Output limitation, password protected
- Pre-definable power-on values
- Ethernet and USB interface
- Integrated Web server for simple remote control via Web browser
Operating modes
The different operating modes of dual-output power supplies offer the option |
- Master – Slave operation
Both power modules are galvanically separated from one another, but are controlled together.
- Parallel operation
Both power modules are switched in parallel mode internally so that the double output power can be drawn from the output terminals of Power Module 1. - Serial operation
Both power modules are switched in serial mode internally. The double output power can be drawn from the respective external terminals.
- Tracking operation
Both power modules are switched in serial mode internally so that, with reference to the two terminals in the middle, plus (+30V) or minus (-30V) voltage can be taken.
Power supply with measuring function
Elabo power supplies, in addition to providing power, are also perfectly suited for precisely measuring actual values. Power and voltage values are measured at intervals of 50ms and can be read out via the interface in the device.
Device limitation
Output voltage and output power can be limited via remote control or also in local mode. This is particularly helpful in training and for protecting sensitive components. Such settings are password protected.
Arbitrary function The lab power supplies have an arbitrary function that allows to program and execute pre-determined functions or freely definable voltage and power progressions. The following functions can be selected: - Sinus - Square - Triangle - Sawtooth - PWM
|
The freely programmable mode allows to program up to 6 progressions of 99 supports each. In this mode one always pre-sets the start value and end value for power and voltage, and also the duration.
In automatic units and encoder versions the arbitrary function can only be used via the interface.
Device overview
Power class | 120W | 120W | 300W | 600W |
Channel | 2 | 2 | 1 | 1 |
Voltage | 2x 0…30V | 2x 0…30V | 0…30V | 0…60V |
Current | 2x 0…2A | 2x 0…2A | 0…10A | 0…10A |
Dimensions | 3HU/42 HP | 6HE/2 WU | 3HE/66 HP | 6HE/2 WU |
Variant: | ||||
Automation | 45-6R | - | 45-6G | - |
Encoder | 45-7R | 34-7T | 45-7G | 34-7L |
Touch | 45-8R | 34-8T | 45-8G | 34-8L |
Data sheet | more |
more |
more |